Tankless units fail in a narrower set of ways than tanks, and most of them are about condition rather than a broken part.
The code comes first
The display is a diagnostic. Codes separate an ignition fault from a flow fault from an exhaust fault, and quoting the code shortens the visit considerably. If the display is blank, the supply is the first question, not the heater.
Scale in the exchanger
The exchanger is a narrow waterway, and the city's minerals coat it. A scaled exchanger loses capacity first — water that used to be hot at full flow arrives cooler — then starts to trip on overheat. This is the single most common tankless fault in this water, and the answer is descaling rather than a part.
Flow and the minimum
Tankless units need a minimum flow to fire. A low-flow shower head, a partially closed valve or a clogged inlet filter can drop below it, and the unit either refuses to start or shuts off mid-draw. Testing flow at the unit separates that from a genuine fault.
Gas capacity, not gas supply
A tankless unit fires hard. If the gas line was sized for a tank, the unit may light and then trip when demand climbs — a capacity problem, not a defective appliance, and one that shows up in cold weather when the incoming water is colder and the burner works longer.
One fixture or all of them
A single misbehaving tap means the fixture. Several means the unit or its supply. That answer decides whether the visit is about the heater at all.