Tankless units fail in a narrow band of ways, and in this city the most common one is entirely predictable.
Scale is the local fault
About 60% of Claremont's water is local groundwater, and heating groundwater concentrates its minerals inside the exchanger. The waterway is narrow, so the effect is felt early: hot water that used to arrive at full flow comes cooler, then the unit trips on overheat. No hardness number is quoted here because none was retrieved for the system, but the direction of the mechanism is not in doubt.
Descaling restores performance while the fouling is still a coating. Once the passage is obstructed, the exchanger is the part that fails.
Decode before diagnosing
The display reports a category — ignition, flow, exhaust, overheat. Reading it aloud on the call is worth more than describing the sound the unit makes.
Flow below the threshold
These units need a minimum flow to fire. A low-flow fixture, a partly closed valve or a blocked inlet filter can sit under it, and the unit then either refuses to start or drops out mid-draw.
Gas capacity, if the line was sized for a tank
A tankless burner draws far more than a storage tank. Where the gas line was sized for the old unit, the appliance may light and then trip under load — a capacity problem rather than a defective part.
One tap or all of them
A single misbehaving fixture is not a heater fault. Several at once means the unit or its supply.