Where the fuel arrives by tank rather than main, some of the faults are upstream of the appliance entirely — and those are the ones worth ruling out first.
Supply before appliance
A low tank, a regulator that has failed, or a second appliance drawing at the same time can all starve a burner. If the cooktop is also weak, the heater is probably not the fault. A tank gauge reading and a quick test at another appliance separate supply from equipment in a couple of minutes.
Pilot and ignition faults
A pilot that lights and dies when the knob is released is a flame-proving part — thermocouple or sensor. A pilot that will not light points at the orifice, the valve or the gas itself. On a propane unit, the air mixture also matters: an appliance set up for natural gas will not run correctly on propane and vice versa.
Venting, and mountain weather
The flue has to carry exhaust out and away. Where the termination sits close to the ground, snow accumulation can block it — a heater that works all summer and trips all winter is often reporting exactly that. The termination and its clearance above the snow line are part of a mountain service.
Flame colour
Blue and steady is correct. Yellow, lifting or sooting means the air or exhaust side is wrong, and the unit should stay off until the venting is checked. On a tight cabin the combustion air supply is part of the same question.
Safety first, always
Gas smell: leave the building and call the utility, whether the fuel arrives by main or tank. Flooded unit: no relighting. Those two are not judgement calls.