Installation here starts with a number most valley installers never look at: the elevation, which for this community is about 4,193 feet.
Derating is not optional
A gas burner sized at sea level delivers too much fuel for the oxygen available up here. Manufacturers publish a derating table for exactly this, and the appliance has to be configured for the altitude it will run at. Skipping it produces sooting, a yellow flame and premature failure — a wrong installation that looks like a defective unit.
The water supply first
The community's public system is the Mt Baldy Homeowners Assn., drawing on two wells and the Bear Canyon Spring. Whether a particular address is on that system, on a private well or on something shared is not something this site knows, and it is the first thing confirmed, because pressure and water condition both shape the installation.
Venting and combustion air in a mountain house
The flue must suit the unit and clear the roof reliably, and snow loading at this elevation is part of that calculation. A termination that is fine in summer can be buried in the first storm. Combustion air in a tightly built house is the other half of the same question.
Sizing against a cold inlet
Incoming water at 4,193 feet is colder than in the valley below, and every heater is rated on temperature rise. A unit that is generous downstairs is merely adequate here, so capacity is chosen from the rise rather than from the tank's nominal volume.
What is confirmed before ordering
Elevation, fuel, venting, supply and access. No price or delivery promise appears on this page, because those follow from the property.